dc.description.abstractComo parte das ações realizadas no âmbito do Plano de Prevenção e Combate a Incêndio (PPCI), o Grupo de Trabalho de Prevenção a Incêndios (GTPI) de um determinado edifício alto com funções administrativas no Estado do Rio Grande do Sul realizou um simulado de evacuação em situação de incêndio. Foi estabelecido um cenário hipotético de incêndio no qual se admitiu que o alarme seria acionado primeiramente no 5º piso, procedendo-se imediatamente à evacuação simultânea de todos os andares. A evacuação foi orientada pelas equipes da Brigada de Incêndio, que conduziram os evacuados até as áreas externas seguras. O exercício foi realizado com aviso prévio dos ocupantes e envolveu diversos órgãos de atendimento e socorro do Município. Observadores do CEPED/RS acompanharam as atividades de coordenação e de evacuação sem interferir no exercício. Observou-se que o simulado foi concluído com êxito e cumpriu os objetivos a que se propunha, contribuindo de forma positiva para a consolidação das competências e procedimentos a adotar em situação de emergência e evacuação. Por outro lado, a anomalia detectada no sistema de alarme de incêndio prejudicou os procedimentos iniciais de evacuação e as falhas encontradas em algumas portas corta fogo podem comprometer a segurança em um incêndio.pt_BR
dc.description.abstractAs part of the actions taken under the Prevention and Fire Fighting Plan, the Working Group for the Prevention of Fires of a certain high building with administrative functions in Rio Grande do Sul conducted a simulated fire evacuation. A hypothetical scenario of fire was established in which it was admitted that the alarm was first triggered on the 5th floor, proceeding immediately to the simultaneous evacuation of all floors. The evacuation was guided by the teams of the Fire Brigade, which led the evacuees to the safe outdoors. The exercise was conducted with notice of the occupants and involved various organs of care and help of the Municipality. Independent observers of CEPED / RS followed the coordination and evacuation activities without interfering in the exercise. It was observed that the simulated was successful and fulfilled the objectives for which they were proposed, contributing positively to the consolidation of skills and procedures to adopt in emergency and evacuation situations. On the other hand, the anomaly detected in the fire alarm system undermined the initial evacuation procedures and flaws found in some fire doors can compromise safety in case of fire.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofRevista FLAMMAE : Revista Científica do Corpo de Bombeiros Militar de Pernambuco [recurso eletrônico]. [Recife]. Vol. 3, n. 6 (jan./jun. 2017), p. 55-73pt_BR
dc.rightsOpen Accessen
dc.subjectSimulateden
dc.subjectProteção contra incêndiopt_BR
dc.subjectFireen
dc.subjectEdifícios altospt_BR
dc.subjectEvacuationen
dc.subjectSegurançapt_BR
dc.subjectHigh buildingen
dc.titleSimulado de evacuação em situação de um incêndio de um edifício alto com funções administrativaspt_BR
dc.title.alternativeSimulated evacuation situation of a fire of a building with high administrative functions en