Mostrar registro simples

dc.contributor.advisorDias, Silvio Luis Pereirapt_BR
dc.contributor.authorRocha, Andrea Anilda Hoffmann dapt_BR
dc.date.accessioned2022-01-21T04:38:28Zpt_BR
dc.date.issued2013pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/234348pt_BR
dc.description.abstractNesse primeiro estudo, um novo material desenvolvido a partir da imobilização da p-benzoquinona imobilizada em um novo material híbrido (CATiSb) de acetato de celulose e óxidos mistos foi aplicado para a oxidação eletrocatalítica de ácido ascórbico (H2AA). O material foi preparado pelo processo de inversão de fase e caracterizado por várias técnicas incluindo microscopia eletrônica de varredura acoplada com espectroscopia de energia dispersa (SEM-EDS), espectroscopia fotoeletrônica de raio-X (XPS), fluorescência de raio-X. Ti e Sb foram mapeados na superfície e observou-se uma distribuição homogênea na matriz. A presença de Ti2p e Sb3d indica a formação de TiO2 e Sb2O5 sendo esses os responsáveis pela rigidez da matriz polimérica. Um eletrodo de pasta de carbono desse material foi usado para estudar a oxidação eletrocatalítica do ácido ascórbico pelas técnicas de voltametria cíclica, cronoamperometria e voltametria de pulso diferencial. O eletrodo apresentou uma rápida resposta, possuindo grande potencial para ser utilizado como sensor eletroquímico para determinação de ácido ascórbico em amostras comerciais. No segundo estudo, foi desenvolvido um novo sensor modificado baseado em compósito condutor feito a partir de acetato de celulose e grafite. O eletrodo foi caracterizado e aplicado para determinação simultânea de dopamina e ácido úrico.pt_BR
dc.description.abstractIn this first study, a novel material made up of p-benzoquinone (BQ) immobilized on a new hybrid of cellulose acetate and mixed metal oxides (CA/TiO2/Sb2O5) was applied to the electrocatalytic oxidation of ascorbic acid (H2AA). The material was prepared by a phase inversion process and characterized by several techniques including scanning electronic microscopy coupled with energy dispersive spectroscopy (SEM-EDS), X-ray photoelectron spectroscopy (XPS), and X-ray fluorescence. Ti and Sb mapping profiles on the surface showed a homogeneous distribution of the matrices. Ti2p and Sb3d doublet indicate that the formation of TiO2 and Sb2O5 is the presumed responsible for the good rigidity of the polymeric matrix. A carbon paste electrode of this material was used to study the electrocatalytic oxidation of ascorbic acid by cyclic voltammetric, chronoamperometric and differential pulse techniques. The electrode had a quick response time, showing great potential to be utilized as an electrochemical sensor for the determination of ascorbic acid in commercial samples. In the second study, a new sensor modified based in cellulose acetate/graphite conduct composite has been developed Modified electrode was characterized and utilized for the simultaneous detection of dopamine and uric aciden
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectEletroquímicapt_BR
dc.subjectMicroscopia eletrônica de varredurapt_BR
dc.subjectAcetato de celulosept_BR
dc.subjectEspectroscopia fotoeletrônica de raio-xpt_BR
dc.titlePreparação e aplicação de eletrodos modificados a base do polímero acetato de celulosept_BR
dc.typeTesept_BR
dc.identifier.nrb000894078pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentInstituto de Químicapt_BR
dc.degree.programPrograma de Pós-Graduação em Químicapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2013pt_BR
dc.degree.leveldoutoradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples