Mostrar registro simples

dc.contributor.advisorLimberger, Renata Pereirapt_BR
dc.contributor.authorBorille, Bruna Tassipt_BR
dc.date.accessioned2021-12-29T04:27:35Zpt_BR
dc.date.issued2014pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/233483pt_BR
dc.description.abstractMilhões de pessoas morrem anualmente vítimas de acidentes de trânsito, sendo grande parte dos acidentes correlacionados ao ato de dirigir sob influência (DUI) de álcool ou drogas. No Brasil, os trabalhadores de postos de gasolina ficam expostos diariamente, durante a jornada de trabalho, ao etanol, presente no etanol combustível e utilizado como aditivo na gasolina. O objetivo deste trabalho foi avaliar a possível interferência do etanol presente nos combustíveis aos quais os frentistas estão expostos diariamente durante a jornada de trabalho, no teste do etilômetro e analisar amostras de fluido oral destes trabalhadores por headspace acoplado a cromatógrafo a gás com detector de massas (HS-CG/EM). Foram convidados a participar do estudo frentistas de 26 postos de gasolina. Primeiramente foi aplicado um questionário, na sequência realizado o teste do etilômetro e coletada amostra de fluido oral através do dispositivo de coleta QuantisalTM para posterior análise em laboratório. Todas as amostras de fluido oral foram analisadas segundo método validado. Em 100% das amostras de fluido oral foi observado presença de etanol e destas, em 72,83% havia presença de etanol em níveis acima do limite de quantificação do método. Com relação ao teste do etilômetro, apenas uma amostra de ar exalado (0,62%) apresentou resultado positivo. As diferenças de concentração de etanol nas diferentes matrizes biológicas são explicadas pelo fato da concentração de etanol ser dependente da concentração de água presente nas matrizes. Os resultados positivos nas amostras de FO e os resultados negativos nas amostras de ar exalado podem ser explicados pela possibilidade do método de análise em FO por HS-CG/EM ser mais sensível do que o teste do etilômetro.pt_BR
dc.description.abstractMillions of people die from traffic accidents, and a large proportion of accidents related to driving under the influence (DUI) of alcohol or drugs. In Brazil, gasoline station attendants are exposed daily during the workday, to ethanol in the fuel and ethanol used as an additive in gasoline. The aim of this study was to evaluate the possible interference of ethanol present in the fuels ethanol and gasoline, to which the attendants are exposed, through breathalyzer and oral fluid (OF) analysis by headspace gas chromatography mass spectrometry (HS-GC/MS). Gasoline stations attendants of 26 gasoline stations were invited to participate in the study. First a questionnaire was fulfilled, followed by the breathalyzer and the OF collection with Quantisal® device for laboratory analysis. All OF samples were analyzed by HS-GC/MS using a validated method. The presence of ethanol was found in 100% of which 72.83% had concentrations above the quantification limit of the method. Regarding the breathalyzer, only one expired air sample (0.62%) had a positive result. The differences in ethanol concentration in different biological matrices are explained by the fact that ethanol concentration is dependent on the concentration of water present in the biological matrix. The positive results in OF samples and negative results in exhaled air samples can be explained by the possibility of the OF analysis by HS-GC/MS to be more sensitive than the breathalyzer.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectEtanolpt_BR
dc.subjectEthanolen
dc.subjectOral fluiden
dc.subjectFrentistaspt_BR
dc.subjectPosto de combustíveis : Trabalhadorpt_BR
dc.subjectExpired air alcohol concentrationen
dc.subjectExposição ocupacionalpt_BR
dc.subjectBlood alcohol concentrationen
dc.subjectGasoline station attendantsen
dc.subjectFluido oralpt_BR
dc.subjectHeadspaceen
dc.subjectCromatografia gasosapt_BR
dc.subjectToxicologia analíticapt_BR
dc.subjectGas chromatography coupled to mass spectrometryen
dc.titleDeterminação de etanol em trabalhadores de postos de gasolinapt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb000970249pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Farmáciapt_BR
dc.degree.programPrograma de Pós-Graduação em Ciências Farmacêuticaspt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2014pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples