dc.description.abstractO objetivo desse estudo foi o de investigar a resistência à fadiga cíclica, flexural, torsional e deflexão angular de instrumentos de níquel-titânio (NiTi) usados para desobturação do canal radicular. Um total de 80 instrumentos de NiTi foram selecionados para esse estudo. As amostras foram divididas em quatro grupos (n = 20), da seguinte forma: Pro-R #25.08; ProDesign Logic RT #25.08; Retratamento MK #25.08; e ProTaper Retratamento D2 #25.08. O teste de fadiga cíclica foi realizado até a fratura em um dispositivo de aço inoxidável personalizado em um equipamento de banho-maria para simular a temperatura corporal. O tempo para fratura foi registrado. O número de ciclos foi calculado. A resistência flexural até 45o, a resistência torsional, e a deflexão angular foram avaliadas. As superfícies das fraturas foram examinadas por microscopia eletrônica de varredura. A análise estatística foi realizada com os testes ANOVA unidirecional e Tukey e Kruskal-Wallis e de Dunn. Pro-R e Logic RT apresentaram a maior fadiga cíclica (P < 0.05). D2 apresentou maior resistência à flexão do que a Pro-R e a Logic-RT (P < 0.05). Logic RT demonstrou o maior torque e deflexão angular (P < 0.05), sem diferenças quando comparado a D2 (P > 0.05). A performance dos instrumentos dependeu das suas características geométricas e tratamentos térmicos.pt_BR
dc.description.abstractThe aim of this study was to investigate the cyclic fatigue, bending, torsional resistance, and angular deflection of nickel-titanium (NiTi) instruments used for root canal desobturation. A total of 80 NiTi instruments were selected for this study. The samples were divided in four groups (n = 20), as follows: Pro-R #25.08; ProDesign Logic RT #25.08; MK Retreatment #25,08; and ProTaper Retreatment D2 #25.08. Cyclic fatigue test was performed until fracture in a custom stainless-steel device with water bath equipment to simulate body temperature. Time to fracture was recorded. Number of cycles was calculated. Resistance to bending at 45o, torsional resistance, and angular deflection were evaluated. The fracture surfaces were examined by scanning electron microscopy. Statistical analysis was performed with one-way ANOVA and Tukey and Kruskal-Wallis and Dunn tests. Pro-R and Logic RT presented the highest cyclic fatigue (P < 0.05). D2 had higher strength to bend than Pro-R and Logic RT (P < 0.05). Logic RT showed the highest torque and angular deflection (P < 0.05), without differences when compared to D2 (P > 0.05). Instruments performances were dependent on their geometrical features and heat treatments.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectBody temperatureen
dc.subjectTemperatura corporalpt_BR
dc.subjectFatigueen
dc.subjectFadigapt_BR
dc.subjectNíquelpt_BR
dc.subjectNickelen
dc.subjectTitâniopt_BR
dc.subjectTitaniumen
dc.subjectFlexural strengthen
dc.subjectResistência à flexãopt_BR
dc.titleAvaliação das propriedades mecânicas de diferentes instrumentos de retratamento de níquel-titâniopt_BR
dc.title.alternativeEvaluation of the mechanical properties of different nickel–titanium retreatment instruments en
dc.typeDissertaçãopt_BR
dc.identifier.nrb001126831pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2021pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples