Mostrar registro simples

dc.contributor.advisorManfro, Roberto Cerattipt_BR
dc.contributor.authorMachado, Fabiani Palagipt_BR
dc.date.accessioned2018-05-31T02:28:21Zpt_BR
dc.date.issued2016pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/178977pt_BR
dc.description.abstractIntrodução: A globulina anti-timocitária (ATG) é um anticorpo policlonal depletor de linfócitos amplamente utilizado no transplante de órgãos. O monitoramento deste agente em receptores de transplante renal pode ser realizado por contagem de linfócitos totais e células T CD3+ no sangue periférico. Objetivo: Avaliar a correlação entre estas duas formas de monitorização. Métodos: Estudo retrospectivo, centro único, avaliou 226 pacientes que receberam enxerto renal entre 2008 e 2013 e que foram tratados com ATG para terapia de indução ou para tratamento de rejeição celular aguda grave. A primeira dose foi administrada no intra-operatório e as subsequentes de acordo com os níveis de células T CD3+ ou número de linfócitos totais no sangue periférico. Os coeficientes de correlação e concordância foram avaliados em amostras pareadas. Resultados: No total 664 amostras pareadas foram analisadas para o número de linfócitos totais e células T CD3+. O coeficiente de correlação de Spearman enre os resultados foi 0.416 (P <0.001) para a amostra geral, 0.435 (P < 0.001) para os pacientes em indução e 0.285 (P<0.005) para os pacientes em tratamento de rejeição. O coeficiente de concordância Kappa entre as amostras gerais foi 0.267 (P < 0.001), 0.280 (P < 0.001) para indução e 0.155 (P<0.081) para pacientes em tratamento. Os parâmetros diagnósticos para a contagem de linfócitos totais foram calculados usando o número de células T CD3+ como padrão-ouro com o ponto de corte de > 20 células/mm³. Na curva ROC o melhor ponto (256 linfócitos/mm3) apresenta área sobre a curva de 0.71 (95% CI: 0.67-0.75) com sensibilidade de 66.8%, especificidade 66.5%, valor preditivo positivo 46.6% e valor preditivo negativo 82.1%. Conclusão: Baseados nestes resultados consideramos que a monitorização da administração e do intervalo das doses de ATG deva ser realizada através da contagem de células T CD3+, por citometria de fluxo, em detrimento dos linfócitos totais no sangue periférico.pt_BR
dc.description.abstractBackground: Anti-thymocyte globulin (ATG) is a preparation of depleting antibodies largely utilized in organ transplantation. The monitoring of this agent in renal transplant recipients can be accomplished by counting total lymphocytes and CD3+T cells in the peripheral blood. Objective: Evaluated the correlation between these two measurements. Methods: Retrospective study, single center study that evaluated 226 patients who received a kidney graft between 2008 and 2013 and where treated with ATG either for induction therapy or for treatment a severe acute cellular rejection. The first dose was given intra-operatively and subsequent doses were administered according to the levels of CD3+ T cells or number of total lymphocytes in the peripheral blood. Correlation and concordance coefficients were evaluated in paired samples. Results: A total of 664 paired samples were analyzed for the number of lymphocytes and CD3+ T. The Spearman’s correlation coefficient between the results was 0.416 (P < 0.001) to all samples, 0.435 (P < 0.001) for induction therapy samples and 0.285 (P<0.005) for therapeutic samples. The Kappa’s concordance coefficient between samples was 0.267 (P < 0.001) to all samples, 0.280 (P < 0.001) for induction therapy samples and 0.155 (P<0.081) for therapeutic samples. The diagnostic parameters for the total lymphocyte counting were calculated using number of CD3+ T cells as the gold standard at the cut off at > 20 cells/mm³. At the ROC curve using the best cut off (256 lymphocytes/mm3) an AUC of 0.71 (95% CI: 0.67-0.75) was found along with a sensitivity 68.8%, specificity 66.5%, positive predictive value 46.6% and negative predictive value 82.1%. Conclusion: Based upon these results it is not possible to reliably replace the flow cytometric assay for CD3+ T cells by the counting of total lymphocytes in the peripheral blood in the monitoring of ATG administration in kidney transplant recipients.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectKidney transplantationen
dc.subjectTransplante de rimpt_BR
dc.subjectImunossupressãopt_BR
dc.subjectT-lymphocytesen
dc.subjectMonitorização imunológicapt_BR
dc.subjectImmunologic monitoringen
dc.subjectImmunosuppressionen
dc.subjectLinfócitos Tpt_BR
dc.titleAvaliação da monitorização da terapia com anticorpos policlonais antilinfócitos T em transplante renal : contagem linfocitária total e de células T CD3+ no sangue periféricopt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb001053544pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Medicinapt_BR
dc.degree.programPrograma de Pós-Graduação em Medicina: Ciências Médicaspt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2017pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples