dc.description.abstractNeste estudo foram avaliados os efeitos do tamanho da partícula e de variações da concentração de sedimentos suspensos (CSS) sobre as leituras de turbidez de três sensores óptico-nefelométricos, com iguais características ópticas e geométricas, utilizando amostras de sedimentos suspensos coletadas na seção fluviométrica da bacia do Turcato (19,5 km²), localizada na Região Sul do Brasil. Omaterial coletado passou por processos de peneiramento e pipetagem para fracionamento nas granulometrias areia e silte. Para cada diâmetro foram separadas frações com diferentes concentrações de sedimentos, variando entre 0,01 e 5,00 g.L-1 . Os resultados demonstram grande influência da CSS e do tamanho da partícula sobre a turbidez. Para qualquer situação, o aumento da turbidez é inverso ao tamanho da partícula e diretamente relacionado ao aumento da CSS. As variações da turbidez, expressas em função da CSS (sensibilidade do sensor), são maiores para menores diâmetros, atingindo valores quase constantes para partículas de areia. As leituras de turbidez dos três sensores não apresentaram diferença significativa no nível de 5% pelo teste de Mann-Whitney rank sum. Para uma mesma CSS, a leitura de turbidez pode ser diferente, conforme a classe granulométrica analisada. A turbidez registrada pelo sensor para a classe silte equivale a uma turbidez observada para uma CSS dez vezes menor para a classe das areias.pt_BR
dc.description.abstractThis study evaluates the effects of particle size and variations of CSS on turbidity readings of three optical-nephelometric sensors using sediment samples collected in the field. Samples were collected in fluviometric station at Turcato basin (19.5 km²), located in the South region of Brazil. The collected material underwent screening and pipetting processes for fractionation in sand and silt grain size. For each diameter were separated fractions with different sediment concentration ranging between 0.01 and 5.00 g.L-1 . The results demonstrate great influence of CSS and particle size on turbidity readings. The increase in turbidity is opposite to particle size and directly related to CSS. Variations in turbidity, expressed in CSS function (sensor sensitivity), are higher for smaller diameters, reaching almost constant values for sand particles. Turbidity readings of the three sensors showed no significant difference in the level of 5% by the Mann-Whitney rank sum test. For a given CSS, the turbidity reading may be different, depending on the granulometric class analyzed. Turbidity recorded by the sensor to the silt-class is equivalent to a sensor response observed for a CSS ten times lower for the sand class.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofEngenharia sanitária e ambiental : órgão oficial de informação técnica da ABES. Vol. 22, n. 2 (mar./abr. 2017), p. 213-219pt_BR
dc.rightsOpen Accessen
dc.subjectWater quality monitoringen
dc.subjectQualidade da agua : Monitoramentopt_BR
dc.subjectConcentração de sólidospt_BR
dc.subjectConcentration of suspended soliden
dc.subjectGranulometriapt_BR
dc.subjectGrain sizeen
dc.subjectOptical sensoren
dc.titleEfeitos do tamanho da partícula e da concentração de sedimentos suspensos sobre a turbidezpt_BR
dc.title.alternativeEffect of particle size and suspended sediment concentration on turbidity en